| Genetron® 11 |
R-11 |
Low-pressure refrigerant for centrifugal chillers. |
| Genetron® 12 |
R-12 |
A widely used refrigerant in reciprocating and rotary type equipment and in some centrifugal designs. |
| Genetron® 13 |
R-13 |
|
| Genetron® 113 |
R-113 |
Genetron® 113 offered low pressures and high gas volumes and was used in primarily in centrifugal chillers. |
| Genetron® 114 |
R-114 |
Genetron® 114 is intermediate in pressure and displacement. Principally used with chillers for higher capacities or for lower evaporator temperature process-type applications. |
| Genetron® 500 |
R-500 |
Genetron® 500, an azeotropic mixture, has slightly higher vapor pressures and provides higher capacities from the same compressor displacement. A mixture of CFC-12 and HFC-152a, R-500 was mostly used in dehumidifiers. |
| Genetron® 502 |
R-502 |
An azeotropic mixture used in low-and medium-temperature refrigeration applications. |
| Genetron® 503 |
R-503 |
|
| Genetron® 123 |
R-123 |
A very low ozone depleting compound that serves as a replacement for CFC-11 in centrifugal chillers. New equipment and retrofits. |
| Genetron® 124 |
R-124 |
A medium pressure refrigerant for chiller applications and cooling systems for high-ambient conditions. |
| Genetron® 22 |
R-22 |
As a refrigerant, operates with higher system pressures but low compressor displacement. Popular in residential, commercial and industrial applications. |
| Genetron® MP39 |
R-401A |
An interim replacement for CFC-12 in medium-temperature commercial refrigeration systems. Medium temperature retrofits. |
| Genetron® MP66 |
R-401B |
An interim replacement for CFC-12 in low-temperature commercial refrigeration systems. Transport refrigeration, low temperature retrofits, retroits including air conditioners and dehumidifiers. |
| Genetron® HP80 |
R-402A |
An interim replacement for retrofitting low- and medium-temperature commercial refrigeration systems. |
| Genetron® HP81 |
R-402B |
An interim replacement for R-502 used mainly for ice machines and soft ice cream machines. |
| Genetron® 409A |
R-409A |
An interim replacement for CFC-12 in refrigeration systems. Low- and medium-temperature retrofits. |
| Genetron® 23 |
R-23 |
A specialty low temperature refrigerant that may be used to replace CFC-13 and R-503 in the low stage of cascade systems. New equipment and retrofits. |
| Genetron® 134a |
R-134a |
Replaces CFC-12 in auto air conditioning and in residential, commercial and industrial refrigeration systems. New equipment. |
| Genetron® 245fa |
R-245fa |
A non-ozone depleting candidate replacement for CFC-11 in centrifugal chillers. New equipment. |
| Genetron® 422D |
R-422D |
A long-term non-ozone depleting replacement for CHFC-22 in low- and medium-temperature commercial refrigeration systems and as retrofit solution in air conditioning installations. Suitable for direct expansion evaporators. Do not use in systems that employ flooded evaporators. New equipment and retrofits. |
| Genetron® 404A |
R-404A |
A long-term non-ozone depleting replacement for R-502 and R-22 in low- and medium-temperature commerical refrigeration systems. |
| Genetron® 407C |
R-407C |
A long-term, non-ozone depleting replacement for HCFC-22 in various air-condiioning applications as well as in positive displacement refrigeration systems. New equipment and retrofits. Not recommended for use in chillers with a flooded evaporator. |
| Genetron® Performax™ LT |
R-407F |
A long-term, non-ozone depleting replacement for HCFC-22 suitable for medium and low temperature applications. Since Genetron Performax LT is a close match to HCFC-22, it also serves as a retrofit fluid in refrigeration applications where HCFC-22 is used. |
| Genetron® 408A |
R-408A |
An interim replacement for retrofitting low-and medium-temperature commercial refrigeration systems. |
| Genetron® AZ-20® |
R-410A |
Widely accepted to replace HCFC-22 in air conditioning and refrigeration applications. New equipment – not for retrofits. |
| Genetron® AZ-50® |
R-507 |
A non-ozone depleting azeotropic mixture of HFC-125 and HFC-143a. It has been primarily designed to replace R-502 in low- and medium-temperature commercial refrigeration applications such as supermarket display cases and ice machines. New equipment and retrofits. |
| 508B |
R-508B |
A non-ozone depleting azeotrope of HFC-23 and FC-116 used to replace CFC-13 and R-503 in the low stage of cascade systems. New equipment and retrofits. |
| Genetron® ST-20™ Flush |
|
Genetron ST-20 Flush uses patented technology to provide excellent cleaning of refrigerant and A/C systems in a very efficient and cost-effective manner. A carefully selected boiling point assures the solvent is easily removed from the system. Genetron ST-20 Flush is effective for use on all HCFC and HFC systems and is compatible with current materials of construction including common seals and gasket materials. |